Mounting bracket IV-H2000MA Keyence
Mounting bracket IV-H2000MA Keyence

We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

IV-H2000MA Keyence Mounting bracket

Manufacturer

Keyence

Country

Japan

Name

IV-H2000MA

Type

Mounting bracket

Description

Long range, Automatic focus model

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications IV-H2000MA

If you are pursuing Keyence IV-H2000MA , call FAMAGA, the world's foremost supplier of industrial equipment. Our company has lasted for more than ten years - these are cycles of experience, which are portrayed in the quality of items and personalseparate attention to each orderer. We understand everyone, who joined with us - hence, our regular buyers pick up the most acceptable purchase terms and discounts on the machine made streamlined equipment market. At this time, there are more than 4500 such buyers, and we constantly form new agreements. More than 700 proceedings are resolved per day, because FAMAGA supplies all over the earth . A well-elaborated logistics network and a partnership network help us to ship our units anywhere in the globe with no delay without discrediting product quality.

A specific source of dignity for FAMAGA is its workers, each of whom contributes to common cause. We call into our team only experts, who already have experience in the range of machine made streamlined equipment.

All products from FAMAGA are affirmed - we are responsible for the cause of our work. At this moment, more than 10 million units of products have been delivered, and this number is ascending every day. We are proud that users choose FAMAGA again and again, and we are glad to make more developed and technologically modern industrial equipment so as keep on top of it.

To request or book, contact us or send a message to the online chat on our site. You can also send a list of the desirable equipment to the email of our company - we will contact you ourselves with a made commercial proposal from FAMAGA.

Features IV-H2000MA

Long range, Automatic focus model
Model IV-H2000MA
Type Long range
Installed distance 300 to 2,000 mm
View Installed distance 300 mm: 45 (H) x 33 (V) mm to installed distance 2,000 mm: 300 (H) x 225 (V) mm
Image sensor Type 1/3 inch monochrome CMOS
Pixel 752 (H) x 480 (V)
Focus adjustment Auto*1
Exposure time 1/10 to 1/25,000
Lights Illumination Infrared LED
Lighting method Pulse lighting/DC lighting is switchable
Tools Type Shape Detection, Colour Area*2, Area*3, Edge Pixels, Width/Height, Diameter, Edge Presence, Pitch, Position Adjustment, High Speed Position Adjustment (1-Axis/2-Axis Adjustment)
Number Detection tools: 16 tools, position adjustment tool: 1 tool*4
Switch settings (programs) 32 programmes
Image history Numbers 300 images*5*6
Condition NG only/All is selectable*6
Analysis information OFF/Statistics/Histograms/Matching rate list is switchable Statistics: Processing time (latest value, MAX, MIN, AVE), number of OKs, number of NGs, trigger numbers, trigger errors, judgement results list by tools Histograms: Histogram, matching degree (latest value, MAX, MIN, AVE), numbers of OKs, numbers of NGs Matching rate list: Judgment results list by tools, matching rate list by tools, judgment bar list by tools*7
Other functions HDR, HighGain, Colour filters*2, Digital zoom*3, Brightness correction, Tilt correction, White balance*2, Mask function, Colour histogram, Test run, ToolAutoTune, Input monitor, Output test, Security settings, Simulator*8, Sensor date/time information addition, Scaling function, Failing sensor list, Failure hold
Indicators PWR/ERR, OUT, TRIG, STATUS, LINK/ACT
Input Type Non-voltage input/voltage input is switchable For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit) For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V)
Inputs 6 inputs (IN1 to IN6)
Function IN1: External trigger, IN2 to IN6: Enable by assigning the optional functions Assignable functions: Programme switching, Clear error, External master image registration
Output Type Open collector output NPN/PNP is switchable, N.O./N.C. is switchable For open collector NPN output: Maximum rating 26.4 V 50 mA, remaining voltage 1.5 V or lower For open collector PNP output: Maximum rating 26.4 V 50 mA, remaining voltage 2 V or lower
Outputs 4 outputs (OUT1 to OUT4)
Function Enable by assigning the optional functions Assignable functions: Total judgement result, RUN, BUSY, Error, Position adjustment result, Judgement result of each tool, Result of the logical operation of each tool, Main unit/expansion unit logical output
Ethernet Standard 100BASE-TX/10BASE-T*9
Connector M12 4pin connector*9
Network function FTP client, EtherNet/IPTM, PROFINET
Rating Power voltage 24 VDC ±10 % (including ripple)
Current consumption 0.6 A or less
Environmental resistance Enclosure rating IP67*10
Ambient temperature 0 to +50 °C (No freezing)
Relative humidity 35 to 85 % RH (No condensation)
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions*11
Shock resistance 500 m/s2, 3 times in each of 6 directions*11
Material Main unit case: Aluminium die-casting, Packing: NBR, Front cover: Acrylic, Mounting adapter: POM
Weight Approx. 270 g
*1 The focusing position can be automatically adjusted at the time of installation. Deactivated during the operation. Focusing position can be registered by programme. *2 Colour type only *3 Possible with both the colour type and monochrome type *4 Tools can be installed by programmes. *5 When using the FTP client function: 210 pictures *6 Saves to the memory in the sensor. The images saved in the sensor can be backed up to the USB memory installed to the intelligent monitor (IV-M30) or to the PC by the software for IV (IV-H1). *7 This can be displayed on the intelligent monitor (IV-M30) or by software for IV (IV-H1). *8 Simulator can be used with the IV software (IV-H1). *9 This is for connection with the intelligent monitor (IV-M30) or software for IV (IV-H1). *10 Except when polarised filter attachment (OP-87436/OP-87437) is mounted *11 Except when IV-G dome attachment (IV-D10) is mounted