'

We are not the manufacturer, authorised distributor or authorised representative of the Kromschroeder / Kromschröder / Kromschroder brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

Kromschroeder / Kromschröder / Kromschroder – page 3

Selling any product from the catalog Kromschroeder / Kromschröder / Kromschroder at good prices

Vendor code
Description
Price
On request
Get a price
REPLACEMENT BCU 480W3P6C0D1000K1E0-/LM400WF3O0E0- Brennersteuerung Vor-Ort Gehäuse, zum Steuern, Zünden und Überwachen von impulsgesteuerten, modulierend oder stufig geregelten Gasbrennern. Für Dauerbetrieb mit Ionisationsüberwachung oder UV-Überwachung mit UV-Sonde UVD. Intermittierender Betrieb mit UV-Sonde UVS. Anzeige des Programmstatus, der Geräteparameter und des Flammensignals. Handbetriebsmodus. Diagnose und Einstellung der Geräteparameter über optische Schnittstelle und PC-Software BCSoft. EU-zertifiziert, FM und EAC zugelassen, zertifiziert für Systeme bis SIL 3 (entspricht PL e). Baureihe: Version für Zünd- und Hauptbrenner Netzspannung: 230 V~, 50/60 Hz Zündtransformator: 8 kV, 12 mA, ED 100 % Flanschplatte: PROFIBUS Ventilüberwachungssystem: Ohne Hochtemperaturbetrieb: Hochtemperaturbetrieb Eingangsfunktion: Ohne Druckwächter: Ohne Anschluss-Stecker: Mit Schraubklemmen Verpackung: Einzelverpackung Energiezufuhr: Über Sicherheitskette Leistungsmodul: Leistungsmodul Baureihe: 400 Netzspannung: 230 V~, 50/60 Hz Luftaktor: Mit Luftventilsteuerung Optionaler Ausgang: Ohne Energiezufuhr: Über Sicherheitskette I004 Flammenüberwachung: Ionisation I050 Funktion Kontakt 80, 81/82: Störmeldung I051 Funktion Kontakt 90, 91/92: Bereitmeldung I052 Funktion Kontakt 95/96: Betriebsmeldung Brenner 1 I053 Funktion Kontakt 95/97: Betriebsmeldung Brenner 2 I054 Funktion Kontakt 85/86, 87: Luftmeldung I061 Funktion Klemme 1: Start 1 I062 Funktion Klemme 2: Reset I063 Funktion Klemme 3: Spülen I064 Funktion Klemme 4: Luft I065 Funktion Klemme 5: Start 2 I066 Funktion Klemme 6: Hochtemperatur I068 Funktion Klemme 35: Sicherheitskette A001 Abschaltschwelle Brenner 1: 2 micro A A002 Abschaltschwelle Brenner 2: 2 micro A A003 Fremdlichtprüfung: Beim Anlauf A006 Hochtemperaturbetrieb: Dauerbetrieb A007 Anlaufversuche Brenner 1: 3 A008 Anlaufversuche Brenner 2: 1 A093 Vorzündzeit tVZ: 0 s A094 1. Sicherheitszeit Anlauf: 3 s A095 Flammenstabilisierungszeit 1 tFS1: 10 s A096 2. Sicherheitszeit Anlauf: 3 s A097 Flammenstabilisierungszeit 2 tFS2: 10 s A078 Brennerapplikation: Brenner 1 und Brenner 2 A079 Zündbrenner: Zum Start A009 Wiederanlauf: Nein A074 Betriebsart Verbrennung: Flammenbetrieb A043 Nachlauf: Aus A039 Nachlaufdauer: 0 s A048 Luftaktorsteuerung: Öffnet bei externer Ansteuerung A129 Aktive Kühlausgänge: Luftaktor A041 Laufzeitauswahl: Ein, für das Anfahren der Positionen für minimale/maximale Leistung A042 Laufzeit: 1 BCU 480W3P6C0D1000K1E0-/LM400WF3O0E0- Burner control unit Housing for on-site mounting, for controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. For continuous operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, FM and EAC approved, certified for systems up to SIL 3 (compliant with PL e). Series: Version for pilot and main burners Mains voltage: 230 V AC, 50/60 Hz Ignition transformer: 8 kV, 12 mA, ED 100 % Flange plate: PROFIBUS Valve proving system: None High temperature operation: High temperature operation Input function: None Pressure switch: None Connection plugs: With screw terminals Packaging: Individual packaging Energy supply: Via safety interlocks Power module: Power module Series: 400 Mains voltage: 230 V AC, 50/60 Hz Air actuator: With air valve control Optional output: None Energy supply: Via safety interlocks I004 Flame control: Ionization I050 Function of contact 80, 81/82: Fault signal I051 Function of contact 90, 91/92: Ready signal I052 Function of contact 95/96: Burner 1 operating signal I053 Function of contact 95/97: Burner 2 operating signal I054 Function of contact 85/86, 87: Air signal I061 Function of terminal 1: Start 1 I062 Function of terminal 2: Reset I063 Function of terminal 3: Purge I064 Function of terminal 4: Air I065 Function of terminal 5: Start 2 I066 Function of terminal 6: High temperature I068 Function of terminal 35: Safety interlocks A001 Switch-off threshold, burner 1: 2 micro A A002 Switch-off threshold, burner 2: 2 micro A A003 Flame simulation check: On start-up A006 High temperature operation: Continuous operation A007 Burner 1 start-up attempts: 3 A008 Burner 2 start-up attempts: 1 A093 Pre-ignition time tVZ: 0 s A094 1st safety time on start-up: 3 s A095 Flame proving period 1 tFS1: 10 s A096 2nd safety time on start-up: 3 s A097 Flame proving period 2 tFS2: 10 s A078 Burner application: Burner 1 and burner 2 A079 Pilot burner: To start A009 Restart: No A074 Combustion mode: Flame mode A043 Over-run: Off A039 Over-run time: 0 s A048 Air actuator control: Opens on external activation A129 Active cooling outputs: Air actuator A041 Selection of running time: On; for approaching the positions for minimum/maximum capacit Stat. Warennummer 90268020 Ursprungsland: DE
1907.09 €
On request
Get a price
On request
Get a price
On request
Get a price
On request
Get a price
On request
Get a price

The site contains only a small part of the catalog items Kromschroeder / Kromschröder / Kromschroder.

If you have not found the article you need, send a request to the mail [email protected] and we will definitely send you a commercial proposal.

You can buy products of other brands